Your browser doesn't support javascript.
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Biosens Bioelectron ; 178: 113041, 2021 Apr 15.
Artículo en Inglés | MEDLINE | ID: covidwho-1051492

RESUMEN

The outbreak of COVID-19 caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has been challenging human health worldwide. Loop-mediated isothermal amplification (LAMP) has been promptly applied to the detection of SARS-CoV-2 owing to its high amplification efficacy and less requirement of the thermal cycler. However, the vast majority of these LAMP-based assays depend on the non-specific detection of LAMP products, which can not discern the undesirable amplificons, likely to yield unreliable results. Herein, a sequence-specific LAMP assay was reported to detect SARS-CoV-2 using proofreading enzyme-mediated probe cleavage (named Proofman), which could realize real-time and visual detection without uncapping. This assay, introducing a proofreading enzyme and the fluorogenic probe to reverse-transcription LAMP (RT-Proofman-LAMP), can specifically detect the SARS-CoV-2 RNA with a detection limit of 100 copies. In addition to the real-time analysis, the assay is capable of endpoint visualization under a transilluminator within 50 min, providing a convenient reporting manner under the setting of point-of-care testing (POCT). In combination with different fluorophores, the one-pot multiplex assay was successfully achieved to detect multiple targets of SARS-CoV-2 and inner control simultaneously. In summary, the development of RT-Proofman-LAMP offers a versatile and highly-specific method for fast field screening and laboratory testing of SARS-CoV-2, making it a promising platform in COVID-19 diagnosis.


Asunto(s)
Prueba de Ácido Nucleico para COVID-19/métodos , COVID-19/diagnóstico , COVID-19/virología , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificación de Ácido Nucleico/métodos , SARS-CoV-2/genética , SARS-CoV-2/aislamiento & purificación , Técnicas Biosensibles/métodos , Técnicas Biosensibles/estadística & datos numéricos , Prueba de Ácido Nucleico para COVID-19/estadística & datos numéricos , Humanos , Límite de Detección , Técnicas de Diagnóstico Molecular/estadística & datos numéricos , Reacción en Cadena de la Polimerasa Multiplex/métodos , Reacción en Cadena de la Polimerasa Multiplex/estadística & datos numéricos , Técnicas de Amplificación de Ácido Nucleico/estadística & datos numéricos , Pandemias , Sistemas de Atención de Punto/estadística & datos numéricos , ARN Viral/análisis , ARN Viral/genética , Sensibilidad y Especificidad
2.
PLoS One ; 15(12): e0243261, 2020.
Artículo en Inglés | MEDLINE | ID: covidwho-1004446

RESUMEN

BACKGROUND: Rapid identification of patients with high suspicion of COVID-19 will become a challenge with the co-circulation of multiple respiratory viruses (RVs). We have identified clinical or biological characteristics to help distinguish SARS-CoV-2 from other RVs. METHODS: We used a prospective cohort including all consecutive patients admitted through the emergency department's (ED) and presenting respiratory symptoms from November 2019 to April 2020. Patients were tested for RV using multiplex polymerase chain reaction (mPCR) and SARS-CoV-2 RT-PCR. RESULTS: 203/508 patients were positive for an RV during the non-SARS-CoV-2 epidemic period (November to February), and 268/596 patients were SARS-CoV-2 positive during the SARS-CoV-2 epidemic (March to April). Younger age, male gender, fever, absence of expectoration and absence of chronic lung disease were statistically associated with SARS-CoV-2 detection. Combining these variables allowed for the distinguishing of SARS-CoV-2 infections with 83, 65, 75 and 76% sensitivity, specificity, PPV and NPV, respectively. CONCLUSION: Patients' characteristics associated with a positive PCR are common between SARS-CoV-2 and other RVs, but a simple discrimination of strong SARS-CoV-2 suspicion with a limited set of clinical features seems possible. Such scoring could be useful but has to be prospectively evaluated and will not eliminate the need for rapid PCR assays.


Asunto(s)
Prueba de Ácido Nucleico para COVID-19/estadística & datos numéricos , COVID-19/epidemiología , Servicio de Urgencia en Hospital/estadística & datos numéricos , Adulto , Anciano , Anciano de 80 o más Años , COVID-19/diagnóstico , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reacción en Cadena de la Polimerasa Multiplex/estadística & datos numéricos , Pruebas en el Punto de Atención/estadística & datos numéricos
3.
Biomed Res Int ; 2020: 7610678, 2020.
Artículo en Inglés | MEDLINE | ID: covidwho-824033

RESUMEN

BACKGROUND: There is a shortage of chemical reagents for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) diagnosis and a surge of SARS-CoV-2 cases, especially in limited-resource settings. Therefore, the combination of an optimal assay kit is necessary. METHODS: We compared the ability to screen SARS-CoV-2 among three primer-probe sets in two different master mixes, Invitrogen™ SuperScript™ III One-Step RT-PCR and LightCycler Multiplex RNA Virus Master. RESULTS: The assay with TIB-Molbiol, IDT, and Phu Sa sets for LightCycler Multiplex RNA Virus Master or Invitrogen™ SuperScript™ III One-Step RT-PCR showed positive results from a single reaction of triplicate in the three days of 4.8 copies per reaction. R squared and amplification efficiency were 0.97 and ranged from 107 to 108%, respectively. CONCLUSIONS: Our findings indicated that TIB-Molbiol, IDT, and Phu Sa primer-probe sets could be beneficial for the laboratory screening of SARS-CoV-2 by RT-qPCR assay of E gene. There is a need to consider the combination of these reagent sets as a new strategy to increase the testing capacity of screening programs for COVID-19.


Asunto(s)
Betacoronavirus/genética , Técnicas de Laboratorio Clínico/métodos , Infecciones por Coronavirus/diagnóstico , Cartilla de ADN/genética , Neumonía Viral/diagnóstico , Sondas ARN/genética , Betacoronavirus/aislamiento & purificación , COVID-19 , Prueba de COVID-19 , Vacunas contra la COVID-19 , Técnicas de Laboratorio Clínico/estadística & datos numéricos , Infecciones por Coronavirus/epidemiología , Infecciones por Coronavirus/virología , Humanos , Reacción en Cadena de la Polimerasa Multiplex/métodos , Reacción en Cadena de la Polimerasa Multiplex/estadística & datos numéricos , Pandemias , Neumonía Viral/epidemiología , Neumonía Viral/virología , ARN Viral/genética , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Reacción en Cadena en Tiempo Real de la Polimerasa/estadística & datos numéricos , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/métodos , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/estadística & datos numéricos , SARS-CoV-2 , Sensibilidad y Especificidad
4.
Biosens Bioelectron ; 166: 112437, 2020 Oct 15.
Artículo en Inglés | MEDLINE | ID: covidwho-645435

RESUMEN

The ongoing global pandemic (COVID-19), caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), has become a huge public health issue. Hence, we devised a multiplex reverse transcription loop-mediated isothermal amplification (mRT-LAMP) coupled with a nanoparticle-based lateral flow biosensor (LFB) assay (mRT-LAMP-LFB) for diagnosing COVID-19. Using two LAMP primer sets, the ORF1ab (opening reading frame 1a/b) and N (nucleoprotein) genes of SARS-CoV-2 were simultaneously amplified in a single-tube reaction, and detected with the diagnosis results easily interpreted by LFB. In presence of FITC (fluorescein)-/digoxin- and biotin-labeled primers, mRT-LAMP produced numerous FITC-/digoxin- and biotin-attached duplex amplicons, which were determined by LFB through immunoreactions (FITC/digoxin on the duplex and anti-FITC/digoxin on the test line of LFB) and biotin/treptavidin interaction (biotin on the duplex and strptavidin on the polymerase nanoparticle). The accumulation of nanoparticles leaded a characteristic crimson band, enabling multiplex analysis of ORF1ab and N gene without instrumentation. The limit of detection (LoD) of COVID-19 mRT-LAMP-LFB was 12 copies (for each detection target) per reaction, and no cross-reactivity was generated from non-SARS-CoV-2 templates. The analytical sensitivity of SARS-CoV-2 was 100% (33/33 oropharynx swab samples collected from COVID-19 patients), and the assay's specificity was also 100% (96/96 oropharynx swab samples collected from non-COVID-19 patients). The total diagnostic test can be completed within 1 h from sample collection to result interpretation. In sum, the COVID-19 mRT-LAMP-LFB assay is a promising tool for diagnosing SARS-CoV-2 infections in frontline public health field and clinical laboratories, especially from resource-poor regions.


Asunto(s)
Betacoronavirus/genética , Betacoronavirus/aislamiento & purificación , Técnicas Biosensibles , Técnicas de Laboratorio Clínico , Infecciones por Coronavirus/diagnóstico , Infecciones por Coronavirus/virología , Pandemias , Neumonía Viral/diagnóstico , Neumonía Viral/virología , Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos , Técnicas Biosensibles/estadística & datos numéricos , COVID-19 , Prueba de COVID-19 , China/epidemiología , Técnicas de Laboratorio Clínico/instrumentación , Técnicas de Laboratorio Clínico/métodos , Técnicas de Laboratorio Clínico/estadística & datos numéricos , Infecciones por Coronavirus/epidemiología , Diseño de Equipo , Estudios de Factibilidad , Humanos , Límite de Detección , Técnicas de Diagnóstico Molecular , Reacción en Cadena de la Polimerasa Multiplex/métodos , Reacción en Cadena de la Polimerasa Multiplex/estadística & datos numéricos , Nanopartículas , Nanotecnología , Técnicas de Amplificación de Ácido Nucleico , Neumonía Viral/epidemiología , ARN Viral/análisis , ARN Viral/genética , SARS-CoV-2 , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA